The main differences between the S1P, S3 and S7 families concern water resistance and outsole requirements. S1P-family footwear includes toe and penetration protection. The S3 family adds upper water penetration and absorption requirements and a cleated outsole. The S7 family also includes whole-footwear water resistance. Read the full suffix to identify the penetration-resistance category. 


Choose footwear for the hazards of the job, then compare the complete marking, fit and product documents. A larger category number does not establish better performance for every workplace.


This guide explains the EN ISO 20345:2022 classification framework. The current BSI edition includes Amendment A1:2024. Always check the edition stated on the product and the requirements applicable to your market and project. 



S1P S3 and S7 at a glance


Category requirement S1P family S3 family S7 family
Full category names S1P / S1PL / S1PS S3 / S3L / S3S S7 / S7L / S7S
Safety toe protection Required Required Required
Penetration resistance Required by type Required by type Required by type
Antistatic properties and heel energy absorption Required Required Required
Upper water resistance WPA Not required Required Required
Whole-footwear water resistance WR Not required Not required Required
Cleated outsole Not required Required Required


'Not required' means the category itself does not require the feature. It does not mean that every product in that category lacks it. The full marking identifies any additional tested properties.


Is S3 waterproof

An S3 marking alone does not establish whole-footwear waterproof performance. WPA concerns the upper material’s resistance to water penetration and absorption. WR concerns the complete footwear. The S7, S7L and S7S categories combine the corresponding S3-family requirements with WR. 


This distinction matters when a shift includes repeated rain, wet ground or other prolonged moisture exposure. For occasional moisture, a water-resistant upper may meet the assessed need. When whole-footwear water resistance is required, look for the corresponding documented WR performance.


A membrane can form part of a waterproof construction, but the category does not specify a membrane brand. Water protection also depends on the boot opening, height, condition and use instructions. A tested WR claim should not be read as unlimited immersion protection. For very wet work, a suitable Wellington-style design may be more appropriate. 


Explore Sanvlar-Tex™ waterproof membrane technology alongside the full marking for the individual model.




Understand P PL and PS

Under the 2022 framework, P identifies a metallic penetration-resistant insert tested with a 4.5 mm nail. PL identifies a non-metallic insert tested with a 4.5 mm nail. PS identifies a non-metallic insert tested with a 3.0 mm nail. The resulting categories include S1PS, S3L and S7S. 


Use the complete classification in the verified product documents. Older 2011 markings must be interpreted in the context of that edition; do not infer the current insert designation from a legacy S1P or S3 label.


A smaller test nail does not make footwear puncture-proof. The sharp objects, loads and contact angles encountered at work can differ from laboratory conditions. Match the insert to the assessed hazard. 


For a model with a Puncture-Resistant Textile Midsole, check whether its full category uses PL or PS. The material description alone is not the complete rating. Learn more about FlexBarrier™ puncture protection.




How to choose safety footwear for your workplace

1. Identify the actual exposure

Record the surfaces, sharp debris, water exposure and other hazards the wearer will encounter. Include movement between areas: a dry warehouse role may also involve a wet loading bay. An industry name alone does not settle the specification. 

2. Match the water requirement

Use the comparison as a starting point: consider the S1P family for dry work with a penetration hazard, the S3 family where a water-resistant upper and cleated outsole are required, and the S7 family where whole-footwear water resistance is required. Check the other risks before choosing.

3. Read additional performance markings

Separate markings describe properties that should be checked individually. A category number does not replace this review. 



Marking Meaning and purchasing check
SR Additional slip-resistance test under the 2022 framework. Consider the actual floor and contaminants.
FO Fuel-oil resistance of the outsole. It is not a general chemical-protection claim.
HRO Outsole resistance to hot contact. Review other heat risks separately.

CI / HI

Cold or heat insulation of the sole complex, as applicable.

ESD Check evidence against the workplace electrostatic-control specification; an S category alone is insufficient.


Ordinary footwear has a basic slip test under the 2022 framework; SR denotes the additional test. Legacy SRA, SRB and SRC markings belong to a different testing framework, so do not rename SRC as SR without matching certification. 


Antistatic properties do not establish electrical insulation or automatically meet an ESD specification. Electrical, chemical, welding and foundry hazards need the relevant specialist assessment and product evidence. 


4. Compare fit and construction

Try footwear with normal work socks. Check heel security, forefoot room and movement comfort, then compare the actual upper, lining, fastening and outsole. Lightweight design, breathability and comfort are model-specific qualities. Use the safety shoe size guide to prepare for fitting.

5.Verify the supplied model

Request the marking, declaration of conformity, certification information and user instructions for the exact model and variant. Match these to the quotation and sample. Check any project requirement for the standard edition and additional properties before placing a bulk order.


Compare relevant Safetoe models

The following examples use the markings stated in Safetoe’s publicly available EU declarations. Check the documents and configuration for the model being supplied. 


Model Marking in the published EU declaration Selection focus
L-7328 S1 PS SR FO S1 base with PS penetration resistance; compare for assessed dry-work needs.
M-8027 S3 FO SR S3 category, with separately stated FO and SR.
M-8552 S7S SR CI HI FO HRO S7 family with PS penetration resistance and the stated additional properties.


The spacing in S1 PS SR FO above follows the published L-7328 declaration. The category explanation elsewhere uses the standard combined form S1PS. M-8552 belongs to the S7S category in its published declaration, so its full designation should be carried into product recommendations. 

View L-7328· View M-8027· View M-8552



FAQ

1. What is the difference between S1P and S3?

In the 2022 framework, the corresponding S3 category adds upper water resistance and a cleated outsole. Compare the complete suffix as well as the number to identify the penetration-resistance type. 

2. What does S7 add to S3?

The corresponding S7 category includes whole-footwear water resistance, WR. It does not automatically establish stronger slip performance or specialist chemical protection. 

3. What does S1PS mean?

S1PS combines the S1 requirements with PS penetration resistance: a non-metallic insert tested using a 3.0 mm nail under the 2022 framework. 

4. Can S3 footwear also have WR performance?

Check the full marking and edition. Some specifications include additional WR performance. The 2022 system incorporates that requirement into S7, S7L and S7S; a bare S3 claim does not establish WR. 

5. Does S7 mean better slip resistance?

No. Compare the applicable slip test and any additional SR marking, then consider the real surface and contaminants. The S7 category number alone does not answer that question. 

6. Are these categories enough for electrical or ESD work?

No. Electrical insulation and electrostatic-control requirements must be checked separately. Antistatic footwear should not be treated as electrically insulating footwear. 



Find the right Safetoe specification

Share the working environment, water exposure, penetration hazards and required markings with our team. We can help you compare the relevant product information and samples for your application.

Review EN ISO 20345 certification information or request product documents and a quotation.



Ready to Partner with Safetoe?
Contact our team for quotations, product samples, worksite solutions and distributor partnerships.
Global Safety Footwear & PPE Solutions
 

Contact Us

Shanghai Langfeng Industrial Co., Ltd. (Safetoe)
Room 905, Building A, No.2, Jibei Road 117, Shanghai, China (Mainland)
Tel : +86-21-5212 7320
Fax : +86-21-5212 1031
Wechat: +86-181 1626 8656
WhatsApp: +86-181 16268656
E-mail:  jay@safetoe.net
 
© 2026 Shanghai Langfeng Industrial Co., Ltd. All Rights Reserved.